DC MCCB

 >  DC MCCB

SNM1-PV DC MCCB

SUNNOM solar DC MCCB, or solar DC Molded Case Circuit Breaker, is specially developed for solar systems. It uses DC-specific arc extinguishing covers and silver points to safeguard the entire system. When a short circuit or overload fault occurs in the system, it can quickly and safely protect it.

Description
Model SNM1-125PV SNM1-250PV SNM1-400PV SNM1-630PV SNM1-800PV SNM1-1250PV
Rated ContinuousCurrent 125 250 400 630 800 1250
Rated Current In(A) 16 20 25
32 40
50 63 80
100 125
100 125 140 160
180 200
225 250
250 315
350 400
400 500
630
630 700
800
800
1000
1250
Rated OperatingVoltage Ùe (v) bC 550V 750V
1000V 1500V
550V 750V
1000V 1500V
750V 1000V 1500V 750V 1000V 1500V 750V 1000V 1500V 750V 1000V 1500V
Rated InsulationVoltage Ui (V) 1500V 1500V 1500V 1500V 1500V 1500V
Uimp (kV) 8kV 8kV 8kV 8kV 8kV 8kV
BreakingCapacity(kA)
lcu
1cs=75%lcu)
L M H L M H L M H L M H L M H L M H
250V 25 35 50 35 50 65 35 50 65 35 50 65 50 65 80 50 65 80
500V 25 25 50 35 35 65 35 35 65 35 35 65 50 50 80 50 50 80
750V 25 15 50 35 25 65 35 25 65 35 25 65 50 35 80 50 35 80
1000V 25 10 50 35 15 65 35 15 65 35 15 65 50 20 80 50 20 80
Mechanical Life 7000 7000 4000 4000 2500 2000
Electrical Life 2000 2000 1000 1000 800 600
Breaking Times (ms) 20 20 20 20 20 20
Installation Location Any place
lsolator Capacity Yes
Standard IEC 60947-2IEC60947-1 GB 14048.1 GB 14048.2
Temperature (°C ) -25 ~+50°C
Protection Degree IP20
Accessory OF/SD/MX
Arcing Distance (mm) ≥50

The core functions of a DC MCCB are overload protection and short-circuit protection. When the current exceeds the rated voltage, the DC molded case circuit breaker will automatically trip to prevent equipment from overheating and damage. When a short-circuit fault occurs, the DC molded case circuit breaker will detect the huge current and trip within milliseconds, isolating the fault and protecting the solar system.

image.jpg

The product is made of flame-retardant materials, DC-specific arc extinguishing cover and silver point, and high-quality accessories to ensure product performance. The product's breaking capacity reaches 20KA, protecting your photovoltaic system.

image (1).jpg

High-hardness operating handle,resistant to compression acd wearSafetyinsulation is not easily damagrd

image (2).jpg

We support ODM/OEM, support parameter customization, V number and A number customization, and make logo customization. As long as you have any needs, we will meet them.

image.png

The product has CE and ISO9001 certification, all production links of the product are carried out in-house, the product quality is safe and reliable

image (3).jpg

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Mobile
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
snm1 pv dc mccb-12

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Mobile
Message
0/1000